- 8-1. Flow single unit Type Hall Sensor
- 냉장고용 유량센서이며 냉장고에 특화된 사출물과 분리형 센서를 조립하여 일체형으로 제작된 센서입니다.
Parameter | Value | Units |
---|---|---|
Supply Voltage | 28 | V |
Supply Current | 50 | mA |
Output Voltage | 28 | V |
Output Current | 50 | mA |
Storage Temperature Range | -50 to 150 | ℃ |
Maximum Junction Temperature | 165 | ℃ |
Operating Temperature Range | Value | Units |
---|---|---|
Temperature Suffix "E" | -40 to 85 | ℃ |
Temperature Suffix "L" | -40 to 150 | ℃ |
Parameter | Value | Units |
---|---|---|
Supply Voltage | 28 | V |
Supply Current | 50 | mA |
Output Voltage | 28 | V |
Output Current | 50 | mA |
Storage Temperature Range | -50 to 150 | ℃ |
Maximum Junction Temperature | 165 | ℃ |
Operating Temperature Range | Value | Units |
---|---|---|
Temperature Suffix "E" | -40 to 85 | ℃ |
Temperature Suffix "L" | -40 to 150 | ℃ |
Parameter | Specification |
---|---|
Working voltage | DC 5V |
Rated voltage | DC 3.5 ~ 24V |
Hall IC Opening Collector | MAX 15mA |
Using Pressure | 0.2 ~ 8.5kgf/cm² |
Using surrounding temp | 5 ~ 60 ℃ |
Using fluid temp | 5 ~ 60 ℃ |
Using Ffluid | (City water or Spring water) |
Flow Rate/Frequency | 0.20cc/Hz ±5% |
Operating flow range | 0.2 ~ 1.6LPM |
Flow Sensing method | Hall IC SWITCHES to using magnet |
Noise level | Be less than 20dB(A) |
Parameter | Specification |
---|---|
Working voltage | DC 5V |
Rated voltage | DC 3.5 ~ 24V |
Hall IC Opening Collector | MAX 15mA |
Using Pressure | 0.3 ~ 8.5kgf/cm² |
Using surrounding temp | 5 ~ 60 ℃ |
Using fluid temp | 5 ~ 50 ℃ |
Using Ffluid | (City water or Spring water) |
Flow Rate/Frequency | 0.28cc/Hz ±5% |
Operating flow range | 0.3 ~ 3.0LPM |
Flow Sensing method | Hall IC SWITCHES to using magnet |
Noise level | Be less than 20dB(A) |
Parameter | Specification |
---|---|
Working voltage | DC 5V |
Rated voltage | DC 3.5 ~ 24V |
Hall IC Opening Collector | MAX 15mA |
Using Pressure | 0.5 ~ 8.5kgf/cm² ( 0.1~0.5kgf/cm² |
Using surrounding temp | 5 ~ 85 ℃ |
Using fluid temp | 5 ~ 95 ℃ |
Using Ffluid | City water or Spring water |
Flow Rate/Frequency | 0.513cc/Hz ±3.5% (0.5LPM~4.0LPM) 0.513cc/Hz ±7% (0.4LPM~0.49LPM) |
Operating flow range | 0.4~4LPM |
Flow Sensing method | Hall IC SWITCHES to using magnet |
Noise level | Be less than 20dB(A) |